Duct CFM Chart: Round and Flex Sizes by Airflow (2026)

A duct CFM chart lists how many cubic feet of air per minute a duct of a given size can carry at a set friction rate. This page gives an indicative chart for round metal, flex and common rectangular ducts, then walks you through using it.

It is part of our ductwork and vents guide.

Key points

  • Residential supply ducts are commonly sized at a friction rate of 0.08 in/wg per 100 feet, and the chart below assumes that rate.
  • A common rule of thumb is about 400 CFM per ton of cooling, so a 3-ton system needs roughly 1,200 CFM.
  • Flex duct typically needs one size larger than metal duct for the same airflow, and it must be stretched tight.
  • Chart values are starting points, because fittings, length, material and static pressure change the airflow you actually get.

Duct CFM chart by duct size

The values below are rounded ranges for straight runs at 0.08 in/wg per 100 feet. Treat them as a planning guide, not a design.

Round duct diameterMetal duct CFM (indicative — rounded, straight run)Flex duct CFM (indicative — one size down from metal)
6 inchAbout 70 to 90 CFMAbout 50 to 60 CFM
8 inchAbout 140 to 170 CFMAbout 110 to 130 CFM
10 inchAbout 200 to 240 CFMAbout 110 to 130 CFM
12 inchAbout 350 to 400 CFMAbout 200 to 240 CFM
14 inchAbout 550 to 650 CFMAbout 350 to 400 CFM
16 inchAbout 800 to 900 CFMAbout 550 to 650 CFM
18 inchAbout 1,100 to 1,300 CFMAbout 800 to 900 CFM

For flex-only sizing, see our flex CFM chart.

Common duct sizes and what they carry

These are common residential sizes with a plain-language note on where each one usually fits.

DuctTypical useRough airflow (indicative)
6 inch roundSingle supply run to a small roomAbout 70 to 90 CFM
8 inch roundSupply branch to a bedroom or officeAbout 140 to 170 CFM
12x12 rectangularTrunk section or large branchAbout 400 to 500 CFM
14 inch roundMain trunk for a 1.5 to 2 ton systemAbout 550 to 650 CFM
18 inch roundMain trunk or return for a 3 ton systemAbout 1,100 to 1,300 CFM

Using the duct CFM chart: step by step

Follow these steps in order, and write each number down as you go.

Find your system's target airflow

Split the airflow across rooms

Pick the duct material

Match each run to a chart row

Size the trunk and return

Adjust for fittings and length

Stretch flex and check the install

Duct CFM chart mistakes to avoid

These errors cause most of the comfort and noise complaints we see in undersized duct layouts.

When to call a licensed HVAC technician about your duct CFM chart

Duct sizing affects equipment life and safety, so some jobs belong with a licensed professional. Check local rules and permits before changing ductwork.

Frequently asked questions

How many CFM for a 14 inch round duct?

A 14 inch round metal duct typically carries about 550 to 650 CFM at 0.08 in/wg per 100 feet (indicative). A 14 inch flex duct carries less, closer to 350 to 400 CFM, and fittings and length reduce both.

What size duct do I need for 1,200 CFM?

A 1,200 CFM system, about 3 tons at 400 CFM per ton, usually calls for an 18 inch round metal trunk (indicative). For flex duct you would normally go one size larger, or split the airflow across several runs.

How many CFM can a 12x12 duct carry?

A 12x12 rectangular duct is roughly equal to a 13 inch round, so it carries about 400 to 500 CFM at a standard residential friction rate (indicative). Aspect ratio, fittings and length can change that figure.

Do return ducts use the same chart?

Yes, the same chart approach applies, but return air CFM must be equal to or greater than supply air CFM. Many installers size return ducts a little larger to keep velocity and noise down.

Get your duct sizes checked

A chart gets you close, but only a measured system confirms real airflow. Quantra HVAC can send a licensed HVAC technician to check your duct sizes, static pressure and return air against your equipment.

Request a quote to get started.

Request a quote

Tell us what you need and we will get back to you.